SP2A/HP3D PR6
Elster PR6
Data Specification Sheet
https://www.elstermetering.com/assets/products/products_elster_files/Falcon_D_1404e_2019.pdf
Installation Instructions
Step 1. Gently unclip and remove the lid from the meter.
Step 2. Remove the foil covering the induction sensor and the plastic O-ring if still present.
Step 3. Clip the PR6 sensor onto the hinge, replacing the lid.
Step 4. Screw the sensor over the face of the dial with the bottom clipping into where the lid clips. Place the anti-tamper caps over the top.
How to Calculate Pulse Rate
Step 1: Check pulse factor on the meter.
In the figure , this meter has a factor of 1 (highlighted in yellow, PR7P:1)
(Insert picture V200 dial face with highlighted k-factor)
Step 2: Check the k-factor on the sensor. This is the second number after the K
(Insert PR6 picture here)
K2 = 100. This output will compensate for reverse flow
Litres per pulse = meter pulse factor PR7 K factor