MultiJet
Zenner Pulse identification – RMC meter
The face of the RMC meter has 4 smaller dials.
In the above example the 4 dials are labelled:
· x 1/10th LITRE
· x 1 LITRE
· x 10 LITRE
· x 100 LITRE
There is a pre-determined cut-out in the face for the sensor to be installed on.
One full revolution of the smaller dial = 1 pulse.
In the above example, the sensor is installed above the “x 10 LITRE” dial.
A pulse is generated after 1 revolution of the dial, and one revolution of this dial = 100 LITRES,
Therefor the Pulse Factor when installed on in this position will be 100L/pulse
Rule: multiply the factor on the dial you’re installing above by x10 to gain the pulse factor.