SP2A/HP3D to Magmaster

SP2A/HP3D to Magmaster

The ADC1 part number has been superseded by the SP2A.
The HP1 part number has been superseded by the HP3D.

 

 

 

The purpose of this guide is to ensure successful installation of Taggle SP2A tag(s)

ABB Guide: https://library.e.abb.com/public/29e9709a43c1dfb3c1257b090058683d/IM_MM-SF_4.pdf

Required:

1 x Taggle SP2A (2x if you require reverse flow as well)

ADC1 Wiring colours

 

 

Instructions for Forward Flow only meters:

  1. After the face of the Magmaster is removed, it will expose the internal circuitry.

  2. Find the terminal block identified by F OUT A & PLS0V

  3. Feed the SP2A cable through a cable gland at the bottom of the Magmaster

  4. Wire in the Red (count) wire into the F OUT A position in the terminal block

  5. Wire in the Blue (ground) wire into the PSD0V position in the terminal block

  6. Trim back and insulate the Yellow and Black cables so they cannot touch each other or ground.

  7. Reinstall the Magmaster cover

 

 

 

If your Magmaster is for forward & reverse flow:

  1. Take your second SP2A and feed the cable through a cable gland underneath

  2. Wire in the Red (count) wire into the F OUT B position in the terminal block

  3. Wire in the Blue (ground) wire into the PSD0V position in the terminal block

  4. Trim back and insulate the Yellow and Black cables so they cannot touch each other or ground.

  5. Clearly mark the reverse flow SP2A to identify it as the reverse flow transmitter

 

Setup of ABB Magmaster

The installer will need to navigate through the ABB Menu to correctly set the Pulse Rate to either 1KL or 10KL depending on available options.

See the below quick reference guide on how to navigate the menu to the “OUTPUT PULSE” section using the Magmaster controls.

Data Capture

All of the below details are required to correctly commission

Tag IDs

Forward: 52405

Reverse: 52406

Meter ID

12X345678

Date/Time

15/07/2014 12:45 PM

Net Meter reading

6542 kL

Forward Meter reading

6547 kL

Reverse Meter reading

5 kL

Pulse Rate

1000L/pulse

(Important to set this to 1KL or 10KL in the ABB settings)

Location

Walkerston Water Tower, Bridge Street

Latitude, Longitude

-21.1599, 149.06506

Standard Install

Yes

Comments